HVAC
Home > Product > Humidity > HVAC
HMD60
±1.5%RH대 정밀 제품으로 알루미늄 바디와 스테인레스 스틸 Probe를 적용하여 산업현장에 적합합니다.
HUMIDITY/
TEMPERATURE
PRODUCT
HMD60
우수한 장기간 안정성과 정확도를 겸비한 고성능 온습도 센서입니다.
■ 표
CATEGORY | MODEL | APPLICATION | FEATURES | TECHNICAL DATA | |
SPEC | OUTPUT | ||||
HMD60 | HMD62 | Duct type | ▪
HVAC 및 Cleanroom 용 ▪알루미늄바디 ▪ Probe 길이: 250mm (HMD60/TMD60은 100mm short probe 선택가능) ▪ IP66(NEMA 4X) |
Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 2 analog outputs, 4…20 mA |
TMD62 | Duct type | Measurement range: T only ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 1 analog output, 4…20 mA | ||
HMD65 | Duct type | Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 2 analog outputs, 0…10 V Digital output: BACnet MS/TP, Modbus RTU |
||
HMD60 | Duct type | Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ Configurable outputs and scale,
short probe option |
||
TMD60 | Duct type | Measurement range: T only ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 1 analog output (4…20 mA,
configurable scale), short probe option |
CATEGORY | MODEL | APPLICATION | FEATURES | TECHNICAL DATA | |
---|---|---|---|---|---|
SPEC | OUTPUT | ||||
HMD60 | HMD62 | Duct type | ▪ HVAC 및 Cleanroom 용 ▪알루미늄바디 ▪ Probe 길이: 250mm (HMD60/TMD60은 100mm short probe 선택가능) ▪ IP66(NEMA 4X) |
Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 2 analog outputs, 4…20 mA |
TMD62 | Duct type | Measurement range: T only▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 1 analog output, 4…20 mA | ||
HMD65 | Duct type | Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 2 analog outputs, 0…10 V Digital output: BACnet MS/TP, Modbus RTU |
||
HMD60 | Duct type | Measurement range: RH & T ▪ RH range: 0…100% RH ▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy ▪ ±1.5%RH (0…90%) ▪ ± 0.1ºC @ 20ºC PT1000 |
▪ Configurable outputs and scale, short probe option |
||
TMD60 | Duct type | Measurement range: T only▪ Temperature range: -20..+80°C (-4...+176°F) Accuracy▪ ± 0.1ºC @ 20ºC PT1000 |
▪ 1 analog output (4…20 mA, configurable scale), short probe option |
13494 경기도 성남시 분당구 대왕판교로 670 판교테크노밸리 유스페이스2 B동 4층 410호
사업자등록번호 : 144-81-08640ㅣFAX: 031-8016-3510